How To Order Model PE Casing Isolators/Spacers




Model PE, 2-Piece Plastic Casing Insulators


Please indicate the following:

  1. Quantity
  2. Model Number = (PE)
  3. Carrier Pipe O.D. (include type of coating and thickness if applicable)
  4. Casing Pipe I.D. (include type of coating and thickness if applicable)
  5. Casing O.D.
  6. Contact your local distributor, or Pipeline Seal and Insulator via Telephone, Fax or e-mail.

Example:

  • Quantity = 24
  • Type Insulator = Plastic PE
  • Carrier Pipe O.D. = 6.00" Nominal - Coating Thickness = 0.313"
  • Casing Pipe I.D. = 9.75" measured - No Coating
  • Casing O.D. = 10.0 Nominal

Size
(Nominal ANSI)

Specification
Data

Approximate
Shipping Data

Carrier

Minimum
Casing

Effective
Skid Height

Number Of
Segments
Per Unit

Number Of
Units Per Case

Per Unit Weights
In Pounds

Per Case
Cu. Ft.

3/4"

2"

5/16"

2

10

.05

.09

1"

3"

1/2"

2

10

.15

.13

1-1/4"

3"

1/2"

2

10

.20

.14

1-1/2"

3"

1/2"

2

10

.20

.18

2"

4"

5/8"

2

10

.50

.34

2-1/2"

5"

5/8"

2

10

.57

.51

3"

6"

5/8"

2

10

.65

.47

4"

6"

9/16"

2

10

.77

.34

4"

8"

1"

2

10

1.00

.47

6"

8"

9/16"

2

10

1.10

.74

6"

10"

1"

2

10

1.65

.91

6"(S)

10"

9/16"

2

10

1.92

.91

8"

10"

9/16"

2

10

1.45

.56

8"

12"

1"

2

10

2.20

1.13

8" (S)

12"

7/8"

2

10

2.29

1.13

10"

14"

7/8"

2

10

2.37

1.35

10" (S)

16"

7/8"

2

10

2.55

1.35

12"

16"

7/8"

2

10

2.72

1.67

NOTES:

  • (S) = Somastic Coated Pipe
  • For larger sizes contact factory for price.
  • For carrier pipes with mechanical joints, consideration should be given to either using a steel casing insulator or making sure that the effective skid height of the plastic insulator will accommodate the O.D. of the mechanical fitting.





Model PE, Multi-Segment Plastic Casing Insulators
    for 4" carrier/casing differentials



Please indicate the following:

  1. Quantity
  2. Model Number
  3. Actual Carrier Pipe O.D. (including coating thickness)
  4. Casing O.D. and Wall Thickness
  5. Contact your local distributor, or Pipeline Seal and Insulator via Telephone, Fax or e-mail.

Example:

  • Quantity = 30
  • Type Insulator = Plastic
  • Carrier Pipe =14" O.D> with 1/8" Coating
  • Casing = 18" O.D. (17.25 I.D.)
  • Ordering Code = 30 - PE 14 x 18

Size
(Nominal ANSI)

Specification
Data

Approximate
Shipping Data

Carrier

Minimum
Casing

Effective
Skid Height

Number Of
Segments
Per Unit

Number Of
Units Per Case

Per Unit Weights
In Pounds

Per Case
Cu. Ft.

Full LS4

Half LS2

12"(S)

18"

1"

3

1

10

4.50

2.64

14"

18"

1"

3

1

10

4.50

2.64

16"

20"

1

4

-

10

5.00

2.98

18"

22"

1"

4

1

10

5.75

3.31

20"

24"

1"

5

-

10

6.25

3.65

22"

26"

1"

5

1

10

7.00

3.95

24"

28"

1"

6

-

10

7.50

4.33

26"

30"

1"

6

1

10

8.25

4.67

28"

32"

1"

7

-

10

8.75

5.01

30"

34"

1"

7

1

10

9.50

5.34

32"

36"

1"

8

-

10

10.00

5.63

34"

38"

1"

8

1

10

10.75

5.97

36"

40"

1"

9

-

10

11.25

6.30

38"

42"

1"

9

1

10

12.00

6.64

40"

44"

1"

10

-

10

12.50

6.98

42"

46"

1"

10

1

10

13.25

7.32

44"

48"

1"

11

-

10

13.75

7.66

46"

50"

1"

11

1

10

14.50

7.99

48"

52"

1"

12

-

10

15.00

8.33

NOTES:

  • (S) = Somastic Coated Pipe
  • For larger sizes contact factory for price.
  • For carrier pipes with mechanical joints, consideration should be given to either using a steel casing insulator or making sure that the effective skid height of the plastic insulator will accommodate the O.D. of the mechanical fitting.





Model PE, Multi-Segment Plastic Casing Insulators
    for 6" carrier/casing differentials



Please indicate the following:

  1. Quantity
  2. Model Number
  3. Actual Carrier Pipe O.D. (including coating thickness)
  4. Casing O.D. and Wall Thickness
  5. Contact your local distributor, or Pipeline Seal and Insulator via Telephone, Fax or e-mail.

Example:

  • Quantity = 30
  • Type Insulator = Plastic
  • Carrier Pipe =14" O.D. with 1/8" Coating
  • Casing = 20" O.D. (19.25 I.D.)
  • Ordering Code = 30 - PE 14 x 20

Size
(Nominal ANSI)

Specification
Data

Approximate
Shipping Data

Carrier

Minimum
Casing

Effective
Skid Height

Number Of
Segments
Per Unit

Number Of
Units Per Case

Per Unit Weights
In Pounds

Per Case
Cu. Ft.

Full HS6

Half HS6A

14"

20"

1.5"

3

1

10

4.50

2.64

16"

22"

1.5"

4

-

10

5.00

2.98

18"

24"

1.5

4

1

10

5.75

3.31

20"

26"

1.5"

5

-

10

6.25

3.65

22"

28"

1.5"

5

1

10

7.00

3.95

24"

30"

1.5"

6

-

10

7.50

4.33

26"

32"

1.5"

6

1

10

8.25

4.67

28"

34"

1.5"

7

-

10

8.75

5.01

30"

36"

1.5"

7

1

10

9.50

5.34

32"

38"

1.5"

8

-

10

10.00

5.63

34"

40"

1.5"

8

1

10

10.75

5.97

36"

42"

1.5"

9

-

10

11.25

6.30

38"

44"

1.5"

9

1

10

12.00

6.64

40"

46"

1.5"

10

-

10

12.50

6.98

42"

48"

1.5"

10

1

10

13.25

7.32

44"

50"

1.5"

11

-

10

13.75

7.66

46"

52"

1.5"

11

1

10

14.50

7.99

48"

54"

1.5"

12

-

10

15.00

8.33

NOTES:

  • For larger sizes contact factory for price.
  • For carrier pipes with mechanical joints, consideration should be given to either using a steel casing insulator or making sure that the effective skid height of the plastic insulator will accommodate the O.D. of the mechanical fitting.